R32 Heat Pump

R32 EVI Split Heating and Cooling Heat Pump

Cedrus Series

140x140

 

►Ecological

R32 has one of the lowest GWPs on the market of 675 and is non-ozone depleting with an ODP of 0. 
Compared to older solutions, it has a 75% lower impact on the environment and global warming. 

140x140

 

►Whilsper Silence

Innovative design provides lower noise level.The use of inverter compressors in outdoor units and exceptionally quiet operation and ensure full comfort of using the heat pump.

140x140

 

►Low Operating Costs

Heat pumps contribute significantly to significant cost savings operation of the house. When using them, the costs of space heating and hot water usable capacity can fall by up to four times. Using a heat pump also allows reduce system maintenance costs.

140x140
Model No.  (Outdoor Unit) AW- 80CL3-BHZW-D 120CL3-BHZW-D 80CL3-BHZW-D 120CL3-BHZW-D
Model No.  (Indoor Unit) AW- 80CL3-BHZN-D 120CL3-BHZN-D 80CL3-BHZN-200L-D 120CL3-BHZN-200L-D
[Space Heating] Ambient Temp. (DB/WB): 7°C/6°C, Water Temp. (Inlet/Outlet): 30°C/35°C.
Heating Capacity  kW 2.60~7.55 3.75~11.15 2.6~7.55 3.75~11.15
Power Input  kW 0.60~1.65 0.87~2.75 0.60~1.65 0.87~2.75
COP kW/kW 4.23~4.65 4.01~4.48 4.23~4.65 4.01~4.48
[Space Heating] Ambient Temp. (DB/WB): 7°C/6°C, Water Temp. (Inlet/Outlet): 40°C/45°C.
Heating Capacity  kW 2.70~8.10 4.42~12.2 2.7~8.1 4.42~12.2
Power Input  kW 0.7~2.35 1.15~3.52 0.7~2.35 1.15~3.52
COP kW/kW 3.36~3.98 3.35~3.95 3.36~3.98 3.35~3.95
[Space Heating] Ambient Temp. (DB/WB): 7°C/6°C, Water Temp. (Inlet/Outlet): 50°C/55°C.
Heating Capacity  kW 2.65~8.13 4.11~11.81 2.65~8.13 4.11~11.81
Power Input  kW 0.94~2.77 1.48~4.00 0.94~2.77 1.48~4.00
COP  kW/kW 2.79~3.01 2.68~3.05 2.79~3.01 2.68~3.05
[Space Heating] Ambient Temp. (DB/WB): -7°C/-8°C, Water Temp. (Inlet/Outlet): 30°C/35°C.
Heating Capacity  kW 2.58~4.72 4.7~8.45 2.58~4.72 4.7~8.45
Power Input  kW 0.96~1.73 1.79~2.69 0.96~1.73 1.79~2.69
COP kW/kW 2.59~2.89 2.58~3.34 2.59~2.89 2.58~3.34
[Space Heating] Ambient Temp. (DB/WB): -7°C/-8°C, Water Temp. (Inlet/Outlet): 40°C/45°C.
Heating Capacity  kW 3.30~6.25 5.4~7.25 3.3~6.25 5.4~7.25
Power Input  kW 1.38~2.64 2.27~3.30 1.38~2.64 2.27~3.30
COP kW/kW 2.28~2.57 2.18~2.58 2.28~2.57 2.18~2.58
[Space Cooling] Ambient Temp. (DB/WB): 35°C/24°C, Water Temp. (Inlet/Outlet): 12°C/7°C.
Heating Capacity  kW 1.80~5.01 2.66~5.62 1.80~5.01 2.66~5.62
Power Input  kW 0.76~1.92 1.14~2.45 0.76~1.92 1.14~2.45
COP kW/kW 2.27~2.81 2.18~2.58 2.27~2.81 2.18~2.58
SCOP, average climate (Water temperature application at 35℃) kW/kW 4.51 4.48 4.51 4.48
SCOP, average climate* (Water temperature application at 55℃) kW/kW 3.41 3.39 3.41 3.39
ErP Level(35℃) tested by EN14825  / A+++ A+++ A+++ A+++
ErP Level(55℃) tested by EN14825 / A++ A++ A++ A++
ErP Level tested by EN16147  /  /  / A++/A  A++/A
Aux. electric heater kW 2.5 2.5 2.5 2.5
Aux. electric heater for domestic hot water kW / / 3.0 3.0
Tank water volume L / / 200L  200L 
Hot water tank inner tank material  /  /  / Duplex 2205
Rated current, Outdoor unit A 6.2 6.2 10.9 10.9
Rated current, Indoor unit  A 0.27 0.27 0.48 0.48
Max operating current outdoor unit A 11.7 16.0 11.7 16.0
Max operating current indoor unit A 11.6 11.6 13.9 13.9
Power Supply / 220-240V~/50Hz
Compressor / Panasonic EVI Twin Rotary
Condenser / Brazed Plate Heat Exchanger
Controller / CAREL Controller
Fan motor / Panasonic DC fan motor
Primiary Water pump / AWMT DC pump (PWM control)
Secondary Water pump for Hot Water System  /  /  / Grundfos Water Pump Grundfos Water Pump
Water Flow m³/h 0.8~1.32 1.2~2.0 0.8~1.31 1.2~1.95
Internal Pressure Drop At Nominal Flow kPa 11 19 11 19
Nominal Air Flow m³/h 3000 3500 3000 3500
Nominal Fan Output  W 110 110 110 110
Maximal Outlet Water Temperature 55
Refrigerant R32 Filling Weight kg 1.3 1.9 1.3 1.9
CO2 Equivalent tone 0.9 1.3 0.9 1.3
Dimensions Outdoor Unit (L×W×H) mm 1065×446×852
Dimensions Indoor Unit  (L×W×H) mm 450×300×850 665×710×1875 (200L)
665×655×2055 (300L)optional
Gas Pipe Connector inch 5/8" 5/8" 5/8" 5/8"
inch 3/8" 3/8" 3/8" 3/8"
Liquid Pipe Connector3/8"
Pipe Connector (Water) inch G1″ external thread
Pipe Connector (Cold Water) inch / / G3/4″ external thread
Pipe Connector (Hot Water) inch / / G3/4″ external thread
Net Weight Outdoor Unit kg 78 80 78 80
Net Weight Indoor Unit / 31 32 / /
Net Weight Indoor Unit(200L/300L) kg / / 163/180 165/182
Operating Ambient Temp. Range  ℃ Heating: -25~35
DHW: -25~35
Cooling: 10~43
Sound Power Level LWA  Indoor/Outdoor dB(A) 40 / 59 42 / 64 40 / 59 42 /64
Sound Pressure Level at 1m Indoor/Outdoor dB(A) 25 / 44 27 / 47 25 / 44 27 / 47

The above data are tested by EN14825. A7/W35℃ means air temp. 7℃,outlet water temp. 35℃

The Sound power level is tested by EN12102

  

 

 

 

 

 

Get a Catalog & Best Price

To get more information, please fill out the form and we'll contact you soon.

Name *

Country or region *

Company

Website

Phone number

Leave your message *

Products Recommended

We value your privacy

We use cookies to enhance your browsing experience.serve personalized ads or content, and analyze our traffic.By clicking "Accept All".you consent to our use ofcookies Cookie Policy.